Untitled Document

 

Members Login
Username 
 
Password 
    Remember Me  
Post Info TOPIC: New Blend Module Is Now Available.


Administrator

Status: Offline
Posts: 4685
Date:
New Blend Module Is Now Available.
Permalink  
 


More info on this flyer. 

http://www.softwashsystems.com/newsletter/Blend_01/

 

Post questions here. I have attached a few pix of different configurations.

 

Thanks,

 

AC

 



Attachments
__________________

AC Lockyer black signature

AC Lockyer

SoftWashSystems.com
   855-763-8669
   ac@SoftWashSystems.com
271 Specialty Point, Sanford, FL 32771



Our Yearly National Convention Softwashapolooza

Our Seven Regional Revolution Camps

Check Out The Family Of SoftWash Systems GoodStewardsLOGOweb2.png Chemicals On Facebook!

10897005_511967222278299_5271292343990797503_n.jpg?oh=3bd386189ce131c6eec283ad37a8e0e5&oe=559C629DSoftWash Systems Final Wash10392462_415375665289411_2337414889228694195_n.jpg?oh=a370df6555b20395455d16e610ec9904&oe=55A67AF21549315_749736438474930_2940956972253314782_n.jpg?oh=c76329ae8dd713b354402883a8e27046&oe=55ACB636SoftWash Systems Rain Fresh1619547_1527992324145386_5503653846693006879_n.jpg?oh=934f2d8ca9dbf7edabdd29b80dd95a47&oe=559A2CFDSoftWash Systems Wood Restore

Map-US-900w150-Authorized.jpg



Lead Tech

Status: Offline
Posts: 478
Date:
Permalink  
 

Very nice AC! I was wondering how long it would take to get this implemented into one of your skid packages.

__________________

Panoramic Clean Logo

Troy Layman
Panoramic Clean
Roof & Exterior Cleaning/Soft Washing
Ashland, VA
www.PanoramicClean.com
Troy@PanoramicClean.com
(757) 562-7216



Lead Tech

Status: Offline
Posts: 478
Date:
Permalink  
 

AC...question about the SH dial mixture. Do you have different print settings for different strengths of SH or CH concentrate on the top dial? Some people use 10% SH, some 12.5%, and others may have access to stronger bleach. If the SH dial is metered for using 10% SH and the SH the SW professional is using is 12.5%, the 4% on the dial would actually be 5%, and the 5% setting would be 6.25% SH.

__________________

Panoramic Clean Logo

Troy Layman
Panoramic Clean
Roof & Exterior Cleaning/Soft Washing
Ashland, VA
www.PanoramicClean.com
Troy@PanoramicClean.com
(757) 562-7216



Freshmen Member

Status: Offline
Posts: 24
Date:
Permalink  
 

So, no more mix tank? It's mixing with customer supply water as it goes through the hose?

__________________

Derek Fontenot

Owner/operator of

Back2Bright, LLC

Structural Soft Washing

Crystal River, FL

(352)445-4840

derek@back2brightllc.com



Lead Tech

Status: Offline
Posts: 478
Date:
Permalink  
 

Derek Fontenot wrote:

So, no more mix tank? It's mixing with customer supply water as it goes through the hose?


 This appears to be an upgrade to a similar system I've seen elsewhere and from I know of it and AC's equipment, the Blend 50 and Blend 100 have three inputs.  One for bleach (SH or pulling from a CH module, adjustable from 0 to 5%), the soap/surfactant input, and the water input.  From what I see it appears the water input would be a water hose connected to the customers water spigot, or a connection from the bulk rinse tank possibly if the customer is on a low performance well.  The Blend 50 would have a 50 gallons SH storage tank, and the Blend 100 would have a 100 gallons of bleach storage. 

There is an 8-gallon saddle buffer tank that I'm not really sure what its purpose is though. I'm assuming it is a mini-water bulk storage tank so it can refill and draw water from this buffer tank to ensure you always have an adequate water supply.  I think you'd be hard pressed to empty an 8 gallon water tank that is being refilled as you spray.  I don't see the 8 gallon tank in any of the pictures that are available so I'm just guessing blindly.  I'm looking forward to a video on this new system.  :0)



__________________

Panoramic Clean Logo

Troy Layman
Panoramic Clean
Roof & Exterior Cleaning/Soft Washing
Ashland, VA
www.PanoramicClean.com
Troy@PanoramicClean.com
(757) 562-7216



SoftWash Systems 5-Star Professional

Status: Offline
Posts: 1168
Date:
Permalink  
 

Troy,

I have been testing the unit for a couple weeks now and it needs to be calibrated a little once you get it. The dials are close, but need a little tweaking based on SH strength and soap concentration. We typically get 15.5% SH from Univar in bulk and we always back down our mixes accordingly. 

Besides not having to mix tanks, the real strength of this unit, is the savings on SH. It seems to use less than when we mix tanks. I think it really takes the human factor/error out. When my guys transfer 5 gallons for a house mix I know that sometimes they transfer 6 or 7. It is just human error. This seems to take tat out of it. 

I used the rig on two large commercial jobs and about 25 houses, with no real issues. 

 



__________________

       roofwizardlogo.png           
Owner - John Aloisio  RRC, RRO 

The Roof Wizard - Roof & Exterior Cleaning

880 S. Grand St. , Hammonton, NJ 08037

John@theroofwizard.net

www.theroofwizard.net

609-705-0093

SoftWashSystems5-STAR_web2.png            SealSeal.png     uamcc-pressure-washing-logo.gif



Administrator

Status: Offline
Posts: 4685
Date:
Permalink  
 

Troy Layman wrote:

AC...question about the SH dial mixture. Do you have different print settings for different strengths of SH or CH concentrate on the top dial? Some people use 10% SH, some 12.5%, and others may have access to stronger bleach. If the SH dial is metered for using 10% SH and the SH the SW professional is using is 12.5%, the 4% on the dial would actually be 5%, and the 5% setting would be 6.25% SH.


 We are making the assumption the SH is 10% like all of our other training videos and systems. Keeping it consistant.

AC



__________________

AC Lockyer black signature

AC Lockyer

SoftWashSystems.com
   855-763-8669
   ac@SoftWashSystems.com
271 Specialty Point, Sanford, FL 32771



Our Yearly National Convention Softwashapolooza

Our Seven Regional Revolution Camps

Check Out The Family Of SoftWash Systems GoodStewardsLOGOweb2.png Chemicals On Facebook!

10897005_511967222278299_5271292343990797503_n.jpg?oh=3bd386189ce131c6eec283ad37a8e0e5&oe=559C629DSoftWash Systems Final Wash10392462_415375665289411_2337414889228694195_n.jpg?oh=a370df6555b20395455d16e610ec9904&oe=55A67AF21549315_749736438474930_2940956972253314782_n.jpg?oh=c76329ae8dd713b354402883a8e27046&oe=55ACB636SoftWash Systems Rain Fresh1619547_1527992324145386_5503653846693006879_n.jpg?oh=934f2d8ca9dbf7edabdd29b80dd95a47&oe=559A2CFDSoftWash Systems Wood Restore

Map-US-900w150-Authorized.jpg



Administrator

Status: Offline
Posts: 4685
Date:
Permalink  
 

Derek Fontenot wrote:

So, no more mix tank? It's mixing with customer supply water as it goes through the hose?


 Customers hose fills a small 7 gallon buffer tank on system.

AC



__________________

AC Lockyer black signature

AC Lockyer

SoftWashSystems.com
   855-763-8669
   ac@SoftWashSystems.com
271 Specialty Point, Sanford, FL 32771



Our Yearly National Convention Softwashapolooza

Our Seven Regional Revolution Camps

Check Out The Family Of SoftWash Systems GoodStewardsLOGOweb2.png Chemicals On Facebook!

10897005_511967222278299_5271292343990797503_n.jpg?oh=3bd386189ce131c6eec283ad37a8e0e5&oe=559C629DSoftWash Systems Final Wash10392462_415375665289411_2337414889228694195_n.jpg?oh=a370df6555b20395455d16e610ec9904&oe=55A67AF21549315_749736438474930_2940956972253314782_n.jpg?oh=c76329ae8dd713b354402883a8e27046&oe=55ACB636SoftWash Systems Rain Fresh1619547_1527992324145386_5503653846693006879_n.jpg?oh=934f2d8ca9dbf7edabdd29b80dd95a47&oe=559A2CFDSoftWash Systems Wood Restore

Map-US-900w150-Authorized.jpg



Junior Member

Status: Offline
Posts: 188
Date:
Permalink  
 

So This unit can be loaded onto the 72" skid? Blend 100 2 tanks then how many additional can fit on that skid? Like a bulk rinse, RO and that is it or more room too? Also 6x Greenwash injection. pre mixed and dispensed out of my container (bucket) or is there a storage built in?

I want to build a full skid but need to do it in stages.

thanks, Jesse

__________________

Mountain Valley Landscape & Property Maintenance, LLP

 

 



Freshmen Member

Status: Offline
Posts: 16
Date:
Permalink  
 

Here is a you tube link to the Blend 50 and 100.

youtu.be/yKtQnj_2y_Q


__________________
Fred


SoftWash Systems Authorized Professional

Status: Offline
Posts: 387
Date:
Permalink  
 

AC,

Just for clarification, you can turn either the bleach valve or the soap valve all the way off, correct? I see there is an "off" on the dial settings, so I'm sure that's the case, but I thought I'd make sure. You never know what application you're going to run in to, and I can already think of a couple applications where one might want to spray just out of the bulk tanks or soap pick-up tube.

__________________

Chad A. Eneix, President, Water Dragon Inc.  chad@waterdragoncleaning.com

www.waterdragoncleaning.com----Southcentral Wisconsin----608-290-9179



Administrator

Status: Offline
Posts: 4685
Date:
Permalink  
 

Chad Eneix wrote:

AC,

Just for clarification, you can turn either the bleach valve or the soap valve all the way off, correct? I see there is an "off" on the dial settings, so I'm sure that's the case, but I thought I'd make sure. You never know what application you're going to run in to, and I can already think of a couple applications where one might want to spray just out of the bulk tanks or soap pick-up tube.


 The small black dial has a 0 (zero) setting which yes is off. Your Blend is going out tomorrow. :)

Thanks,

AC



__________________

AC Lockyer black signature

AC Lockyer

SoftWashSystems.com
   855-763-8669
   ac@SoftWashSystems.com
271 Specialty Point, Sanford, FL 32771



Our Yearly National Convention Softwashapolooza

Our Seven Regional Revolution Camps

Check Out The Family Of SoftWash Systems GoodStewardsLOGOweb2.png Chemicals On Facebook!

10897005_511967222278299_5271292343990797503_n.jpg?oh=3bd386189ce131c6eec283ad37a8e0e5&oe=559C629DSoftWash Systems Final Wash10392462_415375665289411_2337414889228694195_n.jpg?oh=a370df6555b20395455d16e610ec9904&oe=55A67AF21549315_749736438474930_2940956972253314782_n.jpg?oh=c76329ae8dd713b354402883a8e27046&oe=55ACB636SoftWash Systems Rain Fresh1619547_1527992324145386_5503653846693006879_n.jpg?oh=934f2d8ca9dbf7edabdd29b80dd95a47&oe=559A2CFDSoftWash Systems Wood Restore

Map-US-900w150-Authorized.jpg

Page 1 of 1  sorted by
 
Quick Reply

Please log in to post quick replies.

Tweet this page Post to Digg Post to Del.icio.us