Fuses blowing on pump
Permalink  
 


I have a 7gpm pump in a bucket set up. I've used my system on 10+ houses, etc and now it's blowing the fuses. I've replaced the relay and it worked for a couple now it's blowing as soon as I start spraying. Thanks for any suggestions. Ric @ Exterior Visions

__________________
Ric Alessio Interior/Exterior Visions Nashville, TN 800-537-8748 www.ievisions.com


Lead Tech

Status: Offline
Posts: 478
Date:
Permalink  
 

I've not had that issue yet, but go back and double and triple check ever inch of wiring and connections and see if you have a pinched wire, or a bare spot that may be grounding out somewhere. Not to be insulting, but make sure you're using the correct fuses as well. Some fuses are fast blow and some are slow blow to contend with that quick surge of high amperage draw when a motor starts. When electric motors start they draw a very high amount of amps for the first instant until the motor is actually turning. It's possible there is an issue with the pump motor itself as well.

If this doesn't help, hopefully someone may have some more experience and be able to provide better insight.

__________________

Panoramic Clean Logo

Troy Layman
Panoramic Clean
Roof & Exterior Cleaning/Soft Washing
Ashland, VA
www.PanoramicClean.com
Troy@PanoramicClean.com
(757) 562-7216



Freshmen Member

Status: Offline
Posts: 5
Date:
Permalink  
 

Hi Troy,

Thank you, I"ve been using the 25amp fuses white top that was like the original one with the pump.  I was told that it might be pulling to many amps if the PSI is to high when I'm starting and stopping spraying. My guage will go up to 130 PSI sometimes but I don't have a valve to be able to regulate the PSI.  Maybe someone can send me a pic of their set up with their pump and valves.

Thanks, Ric



Attachments
__________________
Ric Alessio Interior/Exterior Visions Nashville, TN 800-537-8748 www.ievisions.com


SoftWash Systems Authorized Professional

Status: Offline
Posts: 387
Date:
Permalink  
 

My skid is a GenIII with bypass and all, so it's a different situation, but I had multiple relays go bad. Part of the problem I think was the fairly high amperage of the pump, I think it says 25 max, and part was the pump's tendency to creep up in pressure, even with a bypass valve. I would say the high pressure is your main problem, coupled with the fairly high amperage draw. I would offer 2 solutions. First, you could try putting in a bypass valve. The second solution would be to try the 5.5gpm pump, it draws less amps. If you don't currently have a back up pump you'll need to get one soon anyway. Personally, and having experienced a similar problem, I think switching pumps would be the way to go. You could end up spending the time and effort putting in a bypass and still have the same problem. Of course, having a bypass would be a good addition anyway.

I ended up putting a 5.5gpm on my rig, and it solved all my problems. You will not lose spray distance or volume, transferring chems will take a very little bit longer, but you'll get longer battery life. The 5.5 amp pump also has no relay, and the ability to tweak the pressure switch up and down.

The 7gpm pump could come in handy as a bleach transfer pump in your shop when you get busier and increase your production volume. Just mount it on the wall next to your bulk bleach.

Also, do like Troy said and check your wires and stuff first, and I assume you are using a good quality deep cycle marine battery with a good charger as well. When I had my starter system, I was an electrical dummy, and I was charging my battery every night with a $15, 1.5 amp battery maintainer. I am still an electrical dummy, but have learned a lot in the last couple years.

__________________

Chad A. Eneix, President, Water Dragon Inc.  chad@waterdragoncleaning.com

www.waterdragoncleaning.com----Southcentral Wisconsin----608-290-9179



Freshmen Member

Status: Offline
Posts: 5
Date:
Permalink  
 

Hi Chad,
Thanks very much, I think it must be a pressure issue but I will check all my wiring connections as well. I do have a good charger and once it's fully charged it goes to trickle charge. I think I will replace the white valve I now have before the gauge with a bypass valve if that's what you would suggest. Or if you feel theres a better location and type of bypass valve that you could reccomend? Where do you buy your valves, like Lowes, etc.?

Appreciate the help.

__________________
Ric Alessio Interior/Exterior Visions Nashville, TN 800-537-8748 www.ievisions.com


SoftWash Systems Pro Staff

Status: Offline
Posts: 666
Date:
Permalink  
 

Ric, there is a small set screw pressure switch on the bottom of the pump, in the form of an allen wrench screw. You can adjust that to keep the pressure shutting off before it goes above 100 PSI.

The Banjo valves are maxed out at 100 PSI, so you can blow the seals off those, which we have done on our Gen 3 skids as well.

We too switched to a 5.5 GPM pump. Call SoftWash Systems and let them know your issues and see if they can help you out.



__________________
Logo

Brandon Vaughn

All-Clean! SoftWash
Gresham, OR
brandon@allcleansoftwash.com
www.allcleansoftwash.com
503.887.6404



Freshmen Member

Status: Offline
Posts: 5
Date:
Permalink  
 

Hi Brandon,

Thanks very much, I will definetly look at adjusting the pressure on the pump first. Also, I've noticed that you are all CH use and wondered how do you get it rinsed off so well. Do you use a rinse agent to apply or just lots of water?

Ric

__________________
Ric Alessio Interior/Exterior Visions Nashville, TN 800-537-8748 www.ievisions.com


SoftWash Systems Pro Staff

Status: Offline
Posts: 666
Date:
Permalink  
 

The trick is to pre-wet, and rinse quickly before it dries, and use lots of water. smile  We use SH more these days since our fleet has grown so much larger in size.



__________________
Logo

Brandon Vaughn

All-Clean! SoftWash
Gresham, OR
brandon@allcleansoftwash.com
www.allcleansoftwash.com
503.887.6404



SoftWash Systems Authorized Professional

Status: Offline
Posts: 387
Date:
Permalink  
 

Ric,

Look for a agricultural fertilizer and spray systems dealer in your area. All of the parts of a quality skid are available there, including a bypass valve. All the components of a quality soft wash system are from agricultural spray equipment. Really what the "throttle valve" or "bypass valve" is is a adjustable external pressure relief valve. The dealer by me is called Fertilizer Dealer Supply, and they are all over at least the midwest.

__________________

Chad A. Eneix, President, Water Dragon Inc.  chad@waterdragoncleaning.com

www.waterdragoncleaning.com----Southcentral Wisconsin----608-290-9179



Freshmen Member

Status: Offline
Posts: 5
Date:
Permalink  
 

Thank you I will find and check out.

__________________
Ric Alessio Interior/Exterior Visions Nashville, TN 800-537-8748 www.ievisions.com


Administrator

Status: Offline
Posts: 4685
Date:
Permalink  
 

Chad Eneix wrote:

My skid is a GenIII with bypass and all, so it's a different situation, but I had multiple relays go bad. Part of the problem I think was the fairly high amperage of the pump, I think it says 25 max, and part was the pump's tendency to creep up in pressure, even with a bypass valve. I would say the high pressure is your main problem, coupled with the fairly high amperage draw. I would offer 2 solutions. First, you could try putting in a bypass valve. The second solution would be to try the 5.5gpm pump, it draws less amps. If you don't currently have a back up pump you'll need to get one soon anyway. Personally, and having experienced a similar problem, I think switching pumps would be the way to go. You could end up spending the time and effort putting in a bypass and still have the same problem. Of course, having a bypass would be a good addition anyway.

I ended up putting a 5.5gpm on my rig, and it solved all my problems. You will not lose spray distance or volume, transferring chems will take a very little bit longer, but you'll get longer battery life. The 5.5 amp pump also has no relay, and the ability to tweak the pressure switch up and down.

The 7gpm pump could come in handy as a bleach transfer pump in your shop when you get busier and increase your production volume. Just mount it on the wall next to your bulk bleach.

Also, do like Troy said and check your wires and stuff first, and I assume you are using a good quality deep cycle marine battery with a good charger as well. When I had my starter system, I was an electrical dummy, and I was charging my battery every night with a $15, 1.5 amp battery maintainer. I am still an electrical dummy, but have learned a lot in the last couple years.


 Spot on Chad. Thanks,

AC



__________________

AC Lockyer black signature

AC Lockyer

SoftWashSystems.com
   855-763-8669
   ac@SoftWashSystems.com
271 Specialty Point, Sanford, FL 32771



Our Yearly National Convention Softwashapolooza

Our Seven Regional Revolution Camps

Check Out The Family Of SoftWash Systems GoodStewardsLOGOweb2.png Chemicals On Facebook!

10897005_511967222278299_5271292343990797503_n.jpg?oh=3bd386189ce131c6eec283ad37a8e0e5&oe=559C629DSoftWash Systems Final Wash10392462_415375665289411_2337414889228694195_n.jpg?oh=a370df6555b20395455d16e610ec9904&oe=55A67AF21549315_749736438474930_2940956972253314782_n.jpg?oh=c76329ae8dd713b354402883a8e27046&oe=55ACB636SoftWash Systems Rain Fresh1619547_1527992324145386_5503653846693006879_n.jpg?oh=934f2d8ca9dbf7edabdd29b80dd95a47&oe=559A2CFDSoftWash Systems Wood Restore

Map-US-900w150-Authorized.jpg

Page 1 of 1  sorted by
 
Quick Reply

Please log in to post quick replies.

Tweet this page Post to Digg Post to Del.icio.us