Untitled Document

 

Members Login
Username 
 
Password 
    Remember Me  
Post Info TOPIC: lost 1/2 my psi on my pressure washer


Junior Member

Status: Offline
Posts: 296
Date:
lost 1/2 my psi on my pressure washer
Permalink  
 


Took my machine out today and the pump is only putting out about half the psi it should be. Been in heated storage all winter anf winterized as well. Thinking it's an air pocket trapped in the pump but not sure. Any ideas? Pump only has 172 hours on it.



__________________

Plymouth Pro Wash

Jeff Thompson

772-539-9654

info@plymouthprowash.com

www.plymouthprowash.com

 

 



SoftWash Systems 5-Star Professional

Status: Offline
Posts: 706
Date:
Permalink  
 

maybe change your pressure gauge - dirt?



__________________

 Tim Teed 

Vesta Wash 

tim@VestaWash.com 

302-559-7533 cell

 

 

 

 



Junior Member

Status: Offline
Posts: 296
Date:
Permalink  
 

Dont have a gauge. Its obvious just by watching and the way my surfacecleaner works something is wrong. Machine puts out 3500 psi 5.5 gpm andI could wash my hands in the water stream.



__________________

Plymouth Pro Wash

Jeff Thompson

772-539-9654

info@plymouthprowash.com

www.plymouthprowash.com

 

 



Sophmore Member

Status: Offline
Posts: 59
Date:
Permalink  
 

Pull the check valves out and check for a broken spring or debris stuck in the valve.


__________________

Maryland Roof Cleaning Company

Serving Maryland & Delaware with Professional Roof & Exterior Cleaning

www.ChesapeakeHydroWash.com

410-479-9744

Chris Gunther - Owner

chris@chesapeakehydrowash.com

 



Administrator

Status: Offline
Posts: 4685
Date:
Permalink  
 

Chris Gunther wrote:

.  Pull the check valves out and check for a broken spring or debris stuck in the valve.


 I think Chris has it

AC



__________________

AC Lockyer black signature

AC Lockyer

SoftWashSystems.com
   855-763-8669
   ac@SoftWashSystems.com
271 Specialty Point, Sanford, FL 32771



Our Yearly National Convention Softwashapolooza

Our Seven Regional Revolution Camps

Check Out The Family Of SoftWash Systems GoodStewardsLOGOweb2.png Chemicals On Facebook!

10897005_511967222278299_5271292343990797503_n.jpg?oh=3bd386189ce131c6eec283ad37a8e0e5&oe=559C629DSoftWash Systems Final Wash10392462_415375665289411_2337414889228694195_n.jpg?oh=a370df6555b20395455d16e610ec9904&oe=55A67AF21549315_749736438474930_2940956972253314782_n.jpg?oh=c76329ae8dd713b354402883a8e27046&oe=55ACB636SoftWash Systems Rain Fresh1619547_1527992324145386_5503653846693006879_n.jpg?oh=934f2d8ca9dbf7edabdd29b80dd95a47&oe=559A2CFDSoftWash Systems Wood Restore

Map-US-900w150-Authorized.jpg



SoftWash Systems Certified Applicator

Status: Offline
Posts: 1115
Date:
Permalink  
 

Also it could be an un loader as well.

__________________

smlogo2.png

Roof%20Cleaning%20Certified%20-%20Signature.pngDiamondRoofCleaning-Insured-1-e1400807362960.jpg 

 

Diamond Roof Cleaning

320 E Collings Drive

Williamstown NJ 08094

Power Washing/Soft Washing in Williamstown,NJ

Roof Cleaning in all of south New Jersey

Call 1-800-Roof-Clean-"Customers only"

All others call 1-609-929-5812



Junior Member

Status: Offline
Posts: 161
Date:
Permalink  
 

Yep one of those 2 usually

__________________

Bill Booz Accuwash LLC

UAMCC director of Standards and Practices

240-425-2845-Cell



Junior Member

Status: Offline
Posts: 296
Date:
Permalink  
 

Check valves were all ok. Called Russ at Southside where I got my machine and it turns out it was my chemical injector for downstreaming. It was defective somehow forcing my water to go into the bypass. So basically half was coming out the gun, and half being dumped back into my tank resulting in low pressure.....weird.

__________________

Plymouth Pro Wash

Jeff Thompson

772-539-9654

info@plymouthprowash.com

www.plymouthprowash.com

 

 



Junior Member

Status: Offline
Posts: 161
Date:
Permalink  
 

That's a surprise. When trouble shooting these issues disconnect all assecories past the pump. Russ is an amazing mechanic.

__________________

Bill Booz Accuwash LLC

UAMCC director of Standards and Practices

240-425-2845-Cell



Sells SoftWash Systems Products

Status: Offline
Posts: 24
Date:
Permalink  
 

Jeff Thompson wrote:

Check valves were all ok. Called Russ at Southside where I got my machine and it turns out it was my chemical injector for downstreaming. It was defective somehow forcing my water to go into the bypass. So basically half was coming out the gun, and half being dumped back into my tank resulting in low pressure.....weird.


 Not so weird really. Many times, when machines sit for a while, a bit of corrosion develops inside the coil. The injector has an orifice in it not much larger than your discharge nozzle, and small pieces of crud can partially or completely block it off, resulting in excess bypass.



__________________

Southside Equipment, Inc.

Louisville, KY

888-243-6506

Russ@PressureWasherKY.us

www.PressureWasherKY.us

Buy SoftWash Systems™ Products

Roof Snot Chlorine Stable Surfactant



Administrator

Status: Offline
Posts: 4685
Date:
Permalink  
 

Russ Johnson wrote:
Jeff:)Thompson wrote:

Check valves were all ok. Called Russ at Southside where I got my machine and it turns out it was my chemical injector for downstreaming. It was defective somehow forcing my water to go into the bypass. So basically half was coming out the gun, and half being dumped back into my tank resulting in low pressure.....weird.


 Not so weird really. Many times, when machines sit for a while, a bit of corrosion develops inside the coil. The injector has an orifice in it not much larger than your discharge nozzle, and small pieces of crud can partially or completely block it off, resulting in excess bypass.


What  he said...........m



__________________

AC Lockyer black signature

AC Lockyer

SoftWashSystems.com
   855-763-8669
   ac@SoftWashSystems.com
271 Specialty Point, Sanford, FL 32771



Our Yearly National Convention Softwashapolooza

Our Seven Regional Revolution Camps

Check Out The Family Of SoftWash Systems GoodStewardsLOGOweb2.png Chemicals On Facebook!

10897005_511967222278299_5271292343990797503_n.jpg?oh=3bd386189ce131c6eec283ad37a8e0e5&oe=559C629DSoftWash Systems Final Wash10392462_415375665289411_2337414889228694195_n.jpg?oh=a370df6555b20395455d16e610ec9904&oe=55A67AF21549315_749736438474930_2940956972253314782_n.jpg?oh=c76329ae8dd713b354402883a8e27046&oe=55ACB636SoftWash Systems Rain Fresh1619547_1527992324145386_5503653846693006879_n.jpg?oh=934f2d8ca9dbf7edabdd29b80dd95a47&oe=559A2CFDSoftWash Systems Wood Restore

Map-US-900w150-Authorized.jpg



Lead Tech Certified

Status: Offline
Posts: 638
Date:
Permalink  
 

I've gotten into the habit a long time ago to always rinse clean, clear water through my downstream injector so as to clean it out and wash as much SH mix away as possible. I now run a quart of BW through it as well to neutralize any SH residue.

__________________

R. Mark Fermoyle - Owner 

Let Us Spray Softwash

Richmond, VA

804-363-3686

Col. 3:23

www.LetUsSpraySoftWash.com

Mark@letusspraysoftwash.com

www.facebook.com/letusspray

 

 

 

 

 

 

 



Junior Member

Status: Offline
Posts: 296
Date:
Permalink  
 

Good advice Mark. I just took the downstreamer right off the rig. Don't see a need for it. I have two 50 gallon stand alone tanks I can draw out of using the Fatboy.

__________________

Plymouth Pro Wash

Jeff Thompson

772-539-9654

info@plymouthprowash.com

www.plymouthprowash.com

 

 



Junior Member

Status: Offline
Posts: 161
Date:
Permalink  
 

The xjet replaced our down streamers for house wash. We modify them from the start. Add a 100 ft. hose and QC to a jug. We wash the roof and house at the same time on most jobs so we need the roof mix hose up there.

That downstreamer is just sucking air when you want more water at low pressure anyway.

__________________

Bill Booz Accuwash LLC

UAMCC director of Standards and Practices

240-425-2845-Cell



Junior Member

Status: Offline
Posts: 161
Date:
Permalink  
 

It's sad but we really throw most of what comes on the x-jet away. I had a dozen downstreamers laying around and couldn't even give them away. Our Landa unit came with an upstream we may use for hydroxide on commercial concrete.

__________________

Bill Booz Accuwash LLC

UAMCC director of Standards and Practices

240-425-2845-Cell

Page 1 of 1  sorted by
 